Source author record

B. A. Moores

B. A. Moores appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2019arXiv

Magnetic resonance force microscopy with a one-dimensional resolution of 0.9 nanometers

Magnetic resonance force microscopy (MRFM) is a scanning probe technique capable of detecting MRI signals from nanoscale sample volumes, providing a paradigm-changing potential for structural biology and medical research. Thus far, however, experiments have not reached suffcient spatial resolution for retrieving meaningful structural information from samples. In this work, we report MRFM imaging scans demonstrating a resolution of 0.9 nm and a localization precision of 0.6 nm in one dimension. Our progress is enabled by an improved spin excitation protocol furnishing us with sharp spatial control on the MRFM imaging slice, combined with overall advances in instrument stability. From a modeling of the slice function, we expect that our arrangement supports spatial resolutions down to 0.3 nm given suffcient signal-to-noise ratio. Our experiment demonstrates the feasibility of sub-nanometer MRI and realizes an important milestone towards the three-dimensional imaging of macromolecular structures.

preprint2015arXiv

Accelerated nanoscale magnetic resonance imaging through phase multiplexing

We report a method for accelerated nanoscale nuclear magnetic resonance imaging by detecting several signals in parallel. Our technique relies on phase multiplexing, where the signals from different nuclear spin ensembles are encoded in the phase of an ultrasensitive magnetic detector. We demonstrate this technique by simultaneously acquiring statistically polarized spin signals from two different nuclear species (1H, 19F) and from up to six spatial locations in a nanowire test sample using a magnetic resonance force microscope. We obtain one-dimensional imaging resolution better than 5 nm, and subnanometer positional accuracy.

preprint2012arXiv

Single-Crystal Diamond Nanomechanical Resonators with Quality Factors exceeding one Million

We present nanofabrication and mechanical measurements of single-crystal diamond cantilevers with thickness down to 85 nm, thickness uniformity better than 20 nm, and lateral dimensions up to 240 um. Quality factors exceeding one million are found at room temperature, surpassing those of state-of-the-art single-crystal silicon cantilevers of similar dimensions by roughly an order of magnitude. Force sensitivities of a few hundred zeptonewtons result for the best cantilevers at millikelvin temperatures. Single-crystal diamond could thus directly improve existing force and mass sensors by a simple substitution of resonator material, and lead to quantum nanomechanical devices with exceptionally low energy dissipation.

preprint2012arXiv

Spin Properties of Very Shallow Nitrogen Vacancy Defects in Diamond

We investigate spin and optical properties of individual nitrogen-vacancy centers located within 1-10 nm from the diamond surface. We observe stable defects with a characteristic optically detected magnetic resonance spectrum down to lowest depth. We also find a small, but systematic spectral broadening for defects shallower than about 2 nm. This broadening is consistent with the presence of a surface paramagnetic impurity layer [Tisler et al., ACS Nano 3, 1959 (2009)] largely decoupled by motional averaging. The observation of stable and well-behaved defects very close to the surface is critical for single-spin sensors and devices requiring nanometer proximity to the target.