Researcher profile

Angelo Bassi

Angelo Bassi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
11works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

Fundamental limits of superconducting quantum computers

The Continuous Spontaneous Localization (CSL) model is an alternative formulation of quantum mechanics which introduces a noise coupled non linearly to the wave function to account for its collapse. We consider CSL effects on quantum computers made of superconducting transmon qubits. As a direct effect CSL reduces quantum superpositions of the computational basis states of the qubits: we show the reduction rate to be negligibly small. However, an indirect effect of CSL, dissipation induced by the noise, also leads transmon qubits to decohere, by generating additional quasiparticles. Since the decoherence rate of transmon qubits depends on the quasiparticle density, by computing their generation rate induced by CSL, we can estimate the corresponding quasiparticle density and thus the limit set by CSL on the performances of transmon quantum computers. We show that CSL could spoil the quantum computation of practical algorithms on large devices. We further explore the possibility of testing CSL effects on superconducting devices.

preprint2022arXiv

MAQRO -- BPS 2023 Research Campaign Whitepaper

The objective of the proposed MAQRO mission is to harness space for achieving long free-fall times, extreme vacuum, nano-gravity, and cryogenic temperatures to test the foundations of physics in macroscopic quantum experiments. This will result in the development of novel quantum sensors and a means to probe the foundations of quantum physics at the interface with gravity. Earlier studies showed that the proposal is feasible but that several critical challenges remain, and key technologies need to be developed. These new technologies will open up the potential for achieving additional science objectives. The proposed research campaign aims to advance the state of the art and to perform the first macroscopic quantum experiments in space. Experiments on the ground, in micro-gravity, and in space will drive the proposed research campaign during the current decade to enable the implementation of MAQRO within the subsequent decade.

preprint2022arXiv

Present status and future challenges of non-interferometric tests of collapse models

The superposition principle is the cornerstone of quantum mechanics, leading to a variety of genuinely quantum effects. Whether the principle applies also to macroscopic systems or, instead, there is a progressive breakdown when moving to larger scales, is a fundamental and still open question. Spontaneous wavefunction collapse models predict the latter option, thus questioning the universality of quantum mechanics. Technological advances allow to challenge collapse models and the quantum superposition principle more and more with a variety of different experiments. Among them, non-interferometric experiments proved to be the most effective in testing these models. We provide an overview of such experiments, including cold atoms, optomechanical systems, X-rays detection, bulk heating as well as comparisons with cosmological observations. We also discuss avenues for future dedicated experiments, which aim at further testing collapse models and the validity of quantum mechanics.

preprint2021arXiv

The Continuous Spontaneous Localization Layering Effect from a Lattice Perspective

For a solid lattice, we rederive the Continuous Spontaneous Localization (CSL) noise total energy gain of a test mass starting from a Lindblad formulation, and from a similar starting point rederive the geometry factor governing center of mass energy gain. We then suggest that the geometry factor can be used as a way to distinguish between low temperature cantilever motion saturation arising from CSL noise, and saturation arising from thermal leakage.

preprint2020arXiv

A macrorealistic test in hybrid quantum optomechanics

We discuss a scheme for macrorealistic theories of the Leggett-Garg form [A. J. Leggett and A. Garg, Phys. Rev. Lett. 54, 857 (1985)]. Our scheme is based on a hybrid optomechanical system. It seems reasonable to test these inequalities with an optomechanical system, since in an optomechanical cavity it is possible to create non-classical states of the mirror through a projective measurement on the cavity field. We will present the protocol to generate such non-classicality for a general optomechanical cavity and after we will carry out a theoretical test for one of the possible formulations of these inequalities using a hybrid optomechanical system. Specifically, the inequality will be investigated for an harmonic oscillator coupled to a two-level system, which replaces the light field of the cavity. The aim is to reproduce, with this system, the evolution of a single spin-1/2 for which the inequality is violated; this is achievable through the conditioning of the two-level system which will be used as an ancilla.

preprint2020arXiv

A Quantum Spectrometer for Arbitrary Noise

We present a technique for recovering the spectrum of a non-Markovian bosonic bath and/or non-Markovian noises coupled to an harmonic oscillator. The treatment is valid under the conditions that the environment is large and hot compared to the oscillator, and that its temporal auto-correlation functions are symmetric with respect to time translation and reflection -- criteria which we consider fairly minimal. We model a demonstration of the technique as deployed in the experimental scenario of a nanosphere levitated in a Paul trap, and show that it would effectively probe the spectrum of an electric field noise source from $10^2\,-\,10^6$ Hz with a resolution inversely proportional to the measurement time. This technique may be deployed in quantum sensing, metrology, computing, and in experimental probes of foundational questions

preprint2020arXiv

Minimum measurement time: lower bound on the frequency cutoff for collapse models

The CSL model predicts a progressive breakdown of the quantum superposition principle, with a noise randomly driving the state of the system towards a localized one, thus accounting for the emergence of a classical world within a quantum framework. In the original model the noise is supposed to be white, but since white noises do not exist in nature, it becomes relevant to identify some of its spectral properties. Experimental data set an upper bound on its frequencies, while in this paper we bound it from below. We do so in two ways: by considering a 'minimal' measurement setup, requiring that the collapse is completed within the measurement time; and in a measurement modeling-independent way, by requiring that the fluctuations average to zero before the measurement time.

preprint2019arXiv

AEDGE: Atomic Experiment for Dark Matter and Gravity Exploration in Space

We propose in this White Paper a concept for a space experiment using cold atoms to search for ultra-light dark matter, and to detect gravitational waves in the frequency range between the most sensitive ranges of LISA and the terrestrial LIGO/Virgo/KAGRA/INDIGO experiments. This interdisciplinary experiment, called Atomic Experiment for Dark Matter and Gravity Exploration (AEDGE), will also complement other planned searches for dark matter, and exploit synergies with other gravitational wave detectors. We give examples of the extended range of sensitivity to ultra-light dark matter offered by AEDGE, and how its gravitational-wave measurements could explore the assembly of super-massive black holes, first-order phase transitions in the early universe and cosmic strings. AEDGE will be based upon technologies now being developed for terrestrial experiments using cold atoms, and will benefit from the space experience obtained with, e.g., LISA and cold atom experiments in microgravity. This paper is based on a submission (v1) in response to the Call for White Papers for the Voyage 2050 long-term plan in the ESA Science Programme. ESA limited the number of White Paper authors to 30. However, in this version (v2) we have welcomed as supporting authors participants in the Workshop on Atomic Experiments for Dark Matter and Gravity Exploration held at CERN: ({\tt https://indico.cern.ch/event/830432/}), as well as other interested scientists, and have incorporated additional material.

preprint2019arXiv

Room temperature test of the Continuous Spontaneous Localization model using a levitated micro-oscillator

The Continuous Spontaneous Localization (CSL) model predicts a tiny break of energy conservation via a weak stochastic force acting on physical systems, which triggers the collapse of the wave function. Mechanical oscillators are a natural way to test such a force; in particular levitated micro-mechanical oscillator has been recently proposed to be an ideal system. We report a proof-of-principle experiment with a micro-oscillator generated by a micro-sphere diamagnetically levitated in a magneto-gravitational trap under high vacuum. Due to the ultra-low mechanical dissipation, the oscillator provides a new upper bound on the CSL collapse rate, which gives an improvement of two orders of magnitude over the previous bounds in the same frequency range, and partially reaches the enhanced collapse rate suggested by Adler. Although being performed at room temperature, our experiment has already exhibits advantages over those operating at low temperatures previously reported. Our results experimentally show the potential of magneto-gravitational levitated mechanical oscillator as a promising method for testing collapse model. Further improvements in cryogenic experiments are discussed.