Researcher profile

Amy N. Bender

Amy N. Bender contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2026arXiv

Unified and consistent structure growth measurements from joint ACT, SPT and \textit{Planck} CMB lensing

We present the tightest cosmic microwave background (CMB) lensing constraints to date on the growth of structure by combining CMB lensing measurements from the Atacama Cosmology Telescope (ACT), the South Pole Telescope (SPT) and \textit{Planck}. Each of these surveys individually provides lensing measurements with similarly high statistical power, achieving signal-to-noise ratios of approximately 40. The combined lensing bandpowers represent the most precise CMB lensing power spectrum measurement to date with a signal-to-noise ratio of 61 and an amplitude of $A_\mathrm{lens}^\mathrm{recon} = 1.025 \pm 0.017$ with respect to the theory prediction from the best-fit CMB \textit{Planck}-ACT cosmology. The bandpowers from all three lensing datasets, analyzed jointly, yield a $1.6\%$ measurement of the parameter combination $S_8^\mathrm{CMBL} \equiv σ_8\,(Ω_m/0.3)^{0.25} = 0.825^{+0.015}_{-0.013}$. Including Dark Energy Spectroscopic Instrument (DESI) Baryon Acoustic Oscillation (BAO) data improves the constraint on the amplitude of matter fluctuations to $σ_8 = 0.829 \pm 0.009$ (a $1.1\%$ determination). When combining with uncalibrated supernovae from \texttt{Pantheon+}, we present a $4\%$ sound-horizon-independent estimate of $H_0=66.4\pm2.5\,\mathrm{km\,s^{-1}\,Mpc^{-1}} $. The joint lensing constraints on structure growth and present-day Hubble rate are fully consistent with a $Λ$CDM model fit to the primary CMB data from \textit{Planck} and ACT. While the precise upper limit is sensitive to the choice of data and underlying model assumptions, when varying the neutrino mass sum within the $Λ\mathrm{CDM}$ cosmological model, the combination of primary CMB, BAO and CMB lensing drives the probable upper limit for the mass sum towards lower values, comparable to the minimum mass prior required by neutrino oscillation experiments.

preprint2022arXiv

Review of Radio Frequency Interference and Potential Impacts on the CMB-S4 Cosmic Microwave Background Survey

CMB-S4 will map the cosmic microwave background to unprecedented precision, while simultaneously surveying the millimeter-wave time-domain sky, in order to advance our understanding of cosmology and the universe. CMB-S4 will observe from two sites, the South Pole and the Atacama Desert of Chile. A combination of small- and large-aperture telescopes with hundreds of thousands of polarization-sensitive detectors will observe in several frequency bands from 20-300 GHz, surveying more than 50 percent of the sky to arcminute resolution with unprecedented sensitivity. CMB-S4 seeks to make a dramatic leap in sensitivity while observing across a broad range of largely unprotected spectrum which is increasingly being utilized for terrestrial and satellite transmissions. Fundamental aspects of CMB instrument technology leave them vulnerable to radio frequency interference (RFI) across a wide range of frequencies, including frequencies outside of their observing bands. Ground-based CMB instruments achieve their extraordinary sensitivities by deploying large focal planes of superconducting bolometers to extremely dry, high-altitude sites, with large fractional bandwidths, wide fields of view, and years of integration time. Suitable observing sites have historically offered significant protection from RFI, both naturally through their extremely remote locations as well as through restrictions on local emissions. Since the coupling mechanisms are complex, safe levels or frequencies of emission that would not interfere with CMB measurements cannot always be determined through straightforward calculations. We discuss models of interference for various types of RFI relevant to CMB-S4, mitigation strategies, and the potential impacts on survey sensitivity.

preprint2022arXiv

Snowmass2021 Cosmic Frontier: Cosmic Microwave Background Measurements White Paper

This is a solicited whitepaper for the Snowmass 2021 community planning exercise. The paper focuses on measurements and science with the Cosmic Microwave Background (CMB). The CMB is foundational to our understanding of modern physics and continues to be a powerful tool driving our understanding of cosmology and particle physics. In this paper, we outline the broad and unique impact of CMB science for the High Energy Cosmic Frontier in the upcoming decade. We also describe the progression of ground-based CMB experiments, which shows that the community is prepared to develop the key capabilities and facilities needed to achieve these transformative CMB measurements.

preprint2021arXiv

Optical leakage mitigation in ortho-mode transducer detectors for microwave applications

Planar ortho-mode transducers (OMTs) are a commonly used method of coupling optical signals between waveguides and on-chip circuitry and detectors. While the ideal OMT-waveguide coupling requires minimal disturbance to the waveguide, when used for mm-wave applications the waveguide is typically constructed from two sections to allow the OMT probes to be inserted into the waveguide. This break in the waveguide is a source of signal leakage and can lead to loss of performance and increased experimental systematic errors. Here we report on the development of new OMT-to-waveguide coupling structures with the goal of reducing leakage at the detector wafer interface. The pixel to pixel optical leakage due to the gap between the coupling waveguide and the backshort is reduced by means of a protrusion that passes through the OMT membrane and electrically connects the two waveguide sections on either side of the wafer. High frequency electromagnetic simulations indicate that these protrusions are an effective method to reduce optical leakage in the gap by ~80% percent, with a ~60% filling factor, relative to an standard OMT coupling architecture. Prototype devices have been designed to characterize the performance of the new design using a relative measurement with varying filling factors. We outline the simulation setup and results, and present a chip layout and sample box that will be used to perform the initial measurements.

preprint2012arXiv

Millimeter-wave bolometer array receiver for the Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument

The Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument is a millimeter-wave cryogenic receiver designed to observe galaxy clusters via the Sunyaev-Zel'dovich effect from the 12 m APEX telescope on the Atacama plateau in Chile. The receiver contains a focal plane of 280 superconducting transition-edge sensor (TES) bolometers instrumented with a frequency-domain multiplexed readout system. The bolometers are cooled to 280 mK via a three-stage helium sorption refrigerator and a mechanical pulse-tube cooler. Three warm mirrors, two 4 K lenses, and a horn array couple the TES bolometers to the telescope. APEX-SZ observes in a single frequency band at 150 GHz with 1' angular resolution and a 22' field-of-view, all well suited for cluster mapping. The APEX-SZ receiver has played a key role in the introduction of several new technologies including TES bolometers, the frequency-domain multiplexed readout, and the use of a pulse-tube cooler with bolometers. As a result of these new technologies, the instrument has a higher instantaneous sensitivity and covers a larger field-of-view than earlier generations of Sunyaev-Zel'dovich instruments. The TES bolometers have a median sensitivity of 890 uKcmb-sqrt(s) (NEy of 3.5e-4 sqrt(s)). We have also demonstrated upgraded detectors with improved sensitivity of 530 uKcmb-sqrt(s) (NEy of 2.2e-4 sqrt(s)). Since its commissioning in April 2007, APEX-SZ has been used to map 48 clusters. We describe the design of the receiver and its performance when installed on the APEX telescope.