Source author record

Alfred Garson

Alfred Garson appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

Optimization of the Design of the Hard X-ray Polarimeter X-Calibur

We report on the optimization of the hard X-ray polarimeter X-Calibur for a high-altitude balloon-flight in the focal plane of the InFOCμS X-ray telescope from Fort Sumner (NM) in Fall 2013. X-Calibur combines a low-Z scintillator slab to Compton-scatter photons with a high-Z Cadmium Zinc Telluride (CZT) detector assembly to photo-absorb the scattered photons. The detector makes use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation. X-Calibur achieves a high detection efficiency of order unity and reaches a sensitivity close to the best theoretically possible. In this paper, we discuss the optimization of the design of the instrument based on Monte Carlo simulations of polarized and unpolarized X-ray beams and of the most important background components. We calculate the sensitivity of the polarimeter for the upcoming balloon flight from Fort Sumner and for additional longer balloon flights with higher throughput mirrors. We conclude by emphasizing that Compton polarimeters on satellite borne missions can be used down to energies of a few keV.

preprint2011arXiv

Design of a Hard X-ray Polarimeter: X-Calibur

We report on Monte Carlo studies of the hard X-ray polarimeter X-Calibur. The polarimeter will be used in the focal plane of a grazing incidence hard X-ray telescope. It combines a low-Z Compton scatterer with a high-Z Cadmium Zinc Telluride (CZT) detector assembly to measure the polarization of 10 keV - 80 keV X-rays. X-Calibur makes use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation. In contrast of competing designs, which use only a small fraction of the incoming X-rays, X-Calibur achieves a high detection efficiency of order unity. In this contributions, we discuss a Monte Carlo study which compares X-Calibur's polarimeteric performance achieved using different scattering materials (Scintillator, Be, LiH, Li), and calculate the sensitivity of X-Calibur when used with different balloon-borne and space-borne mirror assemblies.