Source author record

Alfio T. Puglisi

Alfio T. Puglisi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

Imaging protoplanets: observing transition disks with non-redundant masking

Transition disks, protoplanetary disks with inner clearings, are promising objects in which to directly image forming planets. The high contrast imaging technique of non-redundant masking is well posed to detect planetary mass companions at several to tens of AU in nearby transition disks. We present non-redundant masking observations of the T Cha and LkCa 15 transition disks, both of which host posited sub-stellar mass companions. However, due to a loss of information intrinsic to the technique, observations of extended sources (e.g. scattered light from disks) can be misinterpreted as moving companions. We discuss tests to distinguish between these two scenarios, with applications to the T Cha and LkCa 15 observations. We argue that a static, forward-scattering disk can explain the T Cha data, while LkCa 15 is best explained by multiple orbiting companions.

preprint2014arXiv

Large Binocular Telescope Interferometer Adaptive Optics: On-sky performance and lessons learned

The Large Binocular Telescope Interferometer is a high contrast imager and interferometer that sits at the combined bent Gregorian focus of the LBT's dual 8.4~m apertures. The interferometric science drivers dictate 0.1'' resolution with $10^3-10^4$ contrast at $10~μm$, while the $4~μm$ imaging science drivers require even greater contrasts, but at scales $>$0.2''. In imaging mode, LBTI's Adaptive Optics system is already delivering $4~μm$ contrast of $10^4-10^5$ at $0.3''-0.75''$ in good conditions. Even in poor seeing, it can deliver up to 90\% Strehl Ratio at this wavelength. However, the performance could be further improved by mitigating Non-Common Path Aberrations. Any NCPA remedy must be feasible using only the current hardware: the science camera, the wavefront sensor, and the adaptive secondary mirror. In preliminary testing, we have implemented an ``eye doctor'' grid search approach for astigmatism and trefoil, achieving 5\% improvement in Strehl Ratio at $4~μm$, with future plans to test at shorter wavelengths and with more modes. We find evidence of NCPA variability on short timescales and discuss possible upgrades to ameliorate time-variable effects