Researcher profile

Alexander D. Kaiser

Alexander D. Kaiser contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

Simulations Predict Improved Valve Performance Without Direct Leaflet Intervention After Neonatal Truncus Arteriosus Repair

Truncus arteriosus (TA) is a rare and severe congenital heart disease. Quadricuspid valve morphology occurs in 25% of all TA patients and is linked to regurgitation and increased risk of re-operation. It remains unclear how hemodynamic changes after TA repair alter valve performance. This study simulated pre- and postoperative conditions in a neonatal TA patient to investigate valve performance without direct intervention. We hypothesize that valve performance before and after truncal repair can be predicted in-silico, matching in-vivo imaging and identifying mechanisms how hemodynamic changes after repair will reduce valve regurgitation without direct intervention. Pre- and postoperative CT images of a neonatal patient with quadricuspid valve were segmented. Free edge length and geometric height from the patient's echocardiogram were used to model the valve. For the preoperative condition, ventricular pressures were set equal modeling an unrestricted ventricular septal defect. Systemic and pulmonary resistances were tuned based on the patient's Qp:Qs ratio. For the postoperative condition, boundary conditions were modified to mimic patient-specific hemodynamics after TA repair. The preoperative simulation confirmed mild valve regurgitation seen in-vivo. Interaction between asymmetric flow and surrounding vessel resulted in asymmetric opening and closing. Poor central coaptation led to a central regurgitant jet toward the septum. Altered postoperative hemodynamics improved coaptation and eliminated regurgitation, as seen in-vivo. This modeling approach reproduced in-vivo pre- and postoperative valve performance and identified mechanisms improving coaptation after TA repair. TA repair led to elimination of regurgitation due to enhanced central coaptation. Thus, altered postoperative hemodynamic conditions after TA repair may improve valve performance without direct leaflet intervention.

preprint2022arXiv

Controlled Comparison of Simulated Hemodynamics across Tricuspid and Bicuspid Aortic Valves

Bicuspid aortic valve is the most common congenital heart defect, affecting 1-2% of the global population. Patients with bicuspid valves frequently develop dilation and aneurysms of the ascending aorta. Both hemodynamic and genetic factors are believed to contribute to dilation, yet the precise mechanism underlying this progression remains under debate. Controlled comparisons of hemodynamics in patients with different forms of bicuspid valve disease are challenging because of confounding factors, and simulations offer the opportunity for direct and systematic comparisons. Using fluid-structure interaction simulations, we simulate flows through multiple aortic valve models in a patient-specific geometry. The aortic geometry is based on a healthy patient with no known aortic or valvular disease, which allows us to isolate the hemodynamic consequences of changes to the valve alone. Four fully-passive, elastic model valves are studied: a tricuspid valve and bicuspid valves with fusion of the left- and right-, right- and non-, and non- and left-coronary cusps. The resulting tricuspid flow is relatively uniform, with little secondary or reverse flow, and little to no pressure gradient across the valve. The bicuspid cases show localized jets of forward flow, excess streamwise momentum, elevated secondary and reverse flow, and clinically significant levels of stenosis. Localized high flow rates correspond to locations of dilation observed in patients, with the location related to which valve cusps are fused. Thus, the simulations support the hypothesis that chronic exposure to high local flow contributes to localized dilation and aneurysm formation.

preprint2022arXiv

Modeling the Mitral Valve

This thesis is concerned with modeling and simulation of the mitral valve, one of the four valves in the human heart. The valve is composed of leaflets attached to a ring, the free edges of which are supported by a system of chordae, which themselves are anchored to muscles inside the heart. First, we examine valve anatomy and show the results of original dissections. These display the gross anatomy and information on fiber structure of the mitral valve. Next, we build a model valve following a design-based approach to elasticity. We incorporate information from the dissections to specify the fiber topology of this model. We assume the valve achieves mechanical equilibrium while supporting a static pressure load. The solution to the resulting differential equations determines the pressurized configuration of the valve model. To complete the model we then specify a constitutive law based on experimental stress-strain relations from the literature. Finally, using the immersed boundary method, we simulate the model valve in fluid in a computer test chamber. The aim of this work is to determine the basic principles and mechanisms underlying the anatomy and function of the mitral valve.