Source author record

Alejandro Oscoz

Alejandro Oscoz appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2016arXiv

An instrumental puzzle: the modular integration of AOLI

The Adaptive Optics Lucky Imager, AOLI, is an instrument developed to deliver the highest spatial resolution ever obtained in the visible, 20 mas, from ground-based telescopes. In AOLI a new philosophy of instrumental prototyping has been applied, based on the modularization of the subsystems. This modular concept offers maximum flexibility regarding the instrument, telescope or the addition of future developments.

preprint2016arXiv

Commissioning and First Observations with Wide FastCam at the Telescopio Carlos Sánchez

The FastCam instrument platform, jointly developed by the IAC and the UPCT, allows, in real-time, acquisition, selection and storage of images with a resolution that reaches the diffraction limit of medium-sized telescopes. FastCam incorporates a specially designed software package to analyse series of tens of thousands of images in parallel with the data acquisition at the telescope. Wide FastCam is a new instrument that, using the same software for data acquisition, does not look for lucky imaging but fast observations in a much larger field of view. Here we describe the commissioning process and first observations with Wide FastCam at the Telescopio Carlos Sánchez (TCS) in the Observatorio del Teide.

preprint2014arXiv

High-Resolution Imaging in the Visible on Large Ground-Based Telescopes

Lucky Imaging combined with a low order adaptive optics system has given the highest resolution images ever taken in the visible or near infrared of faint astronomical objects. This paper describes a new instrument that has already been deployed on the WHT 4.2m telescope on La Palma, with particular emphasis on the optical design and the predicted system performance. A new design of low order wavefront sensor using photon counting CCD detectors and multi-plane curvature wavefront sensor will allow virtually full sky coverage with faint natural guide stars. With a 2 x 2 array of 1024 x 1024 photon counting EMCCDs, AOLI is the first of the new class of high sensitivity, near diffraction limited imaging systems giving higher resolution in the visible from the ground than hitherto been possible from space.

preprint2012arXiv

AOLI-- Adaptive Optics Lucky Imager: Diffraction Limited Imaging in the Visible on Large Ground-Based Telescopes

The highest resolution images ever taken in the visible were obtained by combining Lucky Imaging and low order adaptive optics. This paper describes a new instrument to be deployed on the WHT 4.2m and GTC 10.4 m telescopes on La Palma, with particular emphasis on the optical design and the expected system performance. A new design of low order wavefront sensor using photon counting CCD detectors and multi-plane curvature wavefront sensor will allow dramatically fainter reference stars to be used, allowing virtually full sky coverage with a natural guide star. This paper also describes a significant improvements in the efficiency of Lucky Imaging, important advances in wavefront reconstruction with curvature sensors and the results of simulations and sensitivity limits. With a 2 x 2 array of 1024 x 1024 photon counting EMCCDs, AOLI is likely to be the first of the new class of high sensitivity, near diffraction limited imaging systems giving higher resolution in the visible from the ground than hitherto been possible from space.

preprint2012arXiv

High-resolution optical imaging of the core of the globular cluster M15 with FastCam

We present high-resolution I-band imaging of the core of the globular cluster M15 obtained at the 2.5 m Nordic Optical Telescope with FastCam, a low readout noise L3CCD based instrument. Short exposure times (30 ms) were used to record 200000 images (512 x 512 pixels each) over a period of 2 hours 43 min. The lucky imaging technique was then applied to generate a final image of the cluster centre with FWHM ~ 0".1 and 13" x 13" FoV. We obtained a catalogue of objects in this region with a limiting magnitude of I=19.5. I-band photometry and astrometry are reported for 1181 stars. This is the deepest I-band observation of the M15 core at this spatial resolution. Simulations show that crowding is limiting the completeness of the catalogue. At shorter wavelengths, a similar number of objects has been reported using HST/WFPC observations of the same field. The cross-match with the available HST catalogues allowed us to produce colour-magnitude diagrams where we identify new Blue Straggler star candidates and previously known stars of this class.

preprint2012arXiv

The AOLI low-order non-linear curvature wavefront sensor: a method for high sensitivity wavefront reconstruction

The Adaptive Optics Lucky Imager (AOLI) is a new instrument under development to demonstrate near diffraction limited imaging in the visible on large ground-based telescopes. We present the adaptive optics system being designed for the instrument comprising a large stroke deformable mirror, fixed component non-linear curvature wavefront sensor and photon-counting EMCCD detectors. We describe the optical design of the wavefront sensor where two photoncounting CCDs provide a total of four reference images. Simulations of the optical characteristics of the system are discussed, with their relevance to low and high order AO systems. The development and optimisation of high-speed wavefront reconstruction algorithms are presented. Finally we discuss the results of simulations to demonstrate the sensitivity of the system.