Researcher profile

Alberto Ronzani

Alberto Ronzani contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Balanced double-loop mesoscopic interferometer based on Josephson proximity nanojunctions

We report on the fabrication and characterization of a two-terminal mesoscopic interferometer based on three V/Cu/V Josephson junctions having nanoscale cross-section. The junctions have been arranged in a double-ring geometry realized by metallic thin film deposition through a suspended mask defined by electron beam lithography. Although a significant amount of asymmetry between the critical current of each junction is observed we show that the interferometer is able to suppress the supercurrent to a level lower than 6 parts per thousand, being here limited by measurement resolution. The present nano-device is suitable for low-temperature magnetometric and gradiometric measurements over the micrometric scale.

preprint2013arXiv

MicroSQUIDs based on V/Cu/V Josephson nanojunctions

We report on the fabrication and characterization of microSQUID devices based on nanoscale vanadium/copper/vanadium Josephson weak links. Magnetically driven quantum interference patterns have been measured for temperatures in the 0.24 - 2 K range. As magnetometers, these devices obtain flux-to-voltage transfer function values as high as 450 microV/Phi_0 leading to promising magnetic flux resolution Phi_N < 3 microPhi_0 / Hz^(1/2), being here limited by the room temperature preamplification stage. Significant improvements in the flux noise performance figures, which are already competitive with existing state-of-the-art commercial SQUIDs systems, are expected either with cryogenic preamplification or with the adoption of optimized electronic readout stages based on active feedback schemes.