Researcher profile

Alan Sims

Alan Sims contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2022arXiv

Simultaneous High Dynamic Range Algorithm, Testing, and Instrument Simulation

Within an imaging instrument's field of view, there may be many observational targets of interest. Similarly, within a spectrograph's bandpass, there may be many emission lines of interest. The brightness of these targets and lines can be orders of magnitude different, which poses a challenge to instrument and mission design. A single exposure can saturate the bright emission and/or have a low signal to noise ratio (SNR) for faint emission. Traditional high dynamic range (HDR) techniques solve this problem by either combining multiple sequential exposures of varied duration or splitting the light to different sensors. These methods, however, can result in the loss of science capability, reduced observational efficiency, or increased complexity and cost. The simultaneous HDR method described in this paper avoids these issues by utilizing a special type of detector whose rows can be read independently to define zones that are then composited, resulting in areas with short or long exposure measured simultaneously. We demonstrate this technique for the sun, which is bright on disk and faint off disk. We emulated these conditions in the lab to validate the method. We built an instrument simulator to demonstrate the method for a realistic solar imager and input. We then calculated SNRs, finding a value of 45 for a faint coronal mass ejection (CME) and 200 for a bright CME, both at 3.5 $R_{\odot}$ -- meeting or far exceeding the international standard for digital photography that defines a SNR of 10 as acceptable and 40 as excellent. Future missions should consider this type of hardware and technique in their trade studies for instrument design.