Researcher profile

Aisling Ni Annaidh

Aisling Ni Annaidh contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

A combined experimental and numerical study of stab-penetration forces

The magnitude of force used in a stabbing incident can be difficult to quantify, although the estimate given by forensic pathologists is often seen as `critical' evidence in medico-legal situations. The main objective of this study is to develop a quantitative measure of the force associated with a knife stabbing biological tissue, using a combined experimental and numerical technique. A series of stab-penetration tests were performed to quantify the force required for a blade to penetrate skin at various speeds and using different `sharp' instruments. A computational model of blade penetration was developed using ABAQUS/EXPLICIT, a non-linear finite element analysis (FEA) commercial package. This model, which incorporated element deletion along with a suitable failure criterion, is capable of systematically quantifying the effect of the many variables affecting a stab event. This quantitative data could, in time, lead to the development of a predictive model that could help indicate the level of force used in a particular stabbing incident.

preprint2020arXiv

Deficiencies in numerical models of anisotropic nonlinearly elastic materials

Incompressible nonlinearly hyperelastic materials are rarely simulated in Finite Element numerical experiments as being perfectly incompressible because of the numerical difficulties associated with globally satisfying this constraint. Most commercial Finite Element packages therefore assume that the material is slightly compressible. It is then further assumed that the corresponding strain-energy function can be decomposed additively into volumetric and deviatoric parts. We show that this decomposition is not physically realistic, especially for anisotropic materials, which are of particular interest for simulating the mechanical response of biological soft tissue. The most striking illustration of the shortcoming is that with this decomposition, an anisotropic cube under hydrostatic tension deforms into another cube instead of a hexahedron with non-parallel faces. Furthermore, commercial numerical codes require the specification of a `compressibility parameter' (or `penalty factor'), which arises naturally from the flawed additive decomposition of the strain-energy function. This parameter is often linked to a `bulk modulus', although this notion makes no sense for anisotropic solids; we show that it is essentially an arbitrary parameter and that infinitesimal changes to it result in significant changes in the predicted stress response. This is illustrated with numerical simulations for biaxial tension experiments of arteries, where the magnitude of the stress response is found to change by several orders of magnitude when infinitesimal changes in `Poisson's ratio' close to the perfect incompressibility limit of 1/2 are made.

preprint2016arXiv

Non-invasive evaluation of skin tension lines with elastic waves

Background: Since their discovery by Karl Langer in the 19th Century, Skin Tension Lines (STLs) have been used by surgeons to decide the location and orientation of an incision. Although these lines are patient-specific, most surgeons rely on generic maps to determine their orientation. Beyond the imprecise pinch test, there remains no accepted method for determining STLs in vivo. Methods: (i) The speed of an elastic motion travelling radially on the skin of canine cadavers was measured with a commercial device called the Reviscometer. (ii) Similar to the original experiments conducted by Karl Langer, circular excisions were made on the skin and the geometric changes to the resulting wounds and excised samples were used to determine the orientation of STLs. Results: A marked anisotropy in the speed of the elastic wave travelling radially was observed. The orientation of the fastest wave was found to correlate with the orientation of the elongated wound (P<0.001, R^2 = 74%). Similarly, the orientation of fastest wave was the same for both in vivo and excised isolated samples, indicating that the STLs have a structural basis. Resulting wounds expanded by an average area of 9% (+16% along STL and -10% across) while excised skin shrunk by an average area of 33% (23% along STL and 10% across). Conclusion: Elastic surface wave propagation has been validated experimentally as a robust method for determining the orientation of STLs non-destructively and non-invasively. This study has implications for the identification of STLs and for the prediction of skin tension levels, both important factors in both human and veterinary reconstructive surgery.

preprint2013arXiv

Bending instabilities of soft tissues

Rubber components and soft tissues are often subjected to large bending deformations &#34;in service&#34;. The circumferential line elements on the inner face of a bent block can contract up to a certain critical stretch ratio lambda_cr (say) before bifurcation occurs and axial creases appear. For several models used to describe rubber, it is found that lambda_cr = 0.56, allowing for a 44% contraction. For models used to describe arteries it is found, somewhat surprisingly, that the strain-stiffening effect promotes instability. For example, the models used for the artery of a 70 year old human predict that lambda_cr = 0.73, allowing only for a 27% contraction. Tensile experiments conducted on pig skin indicate that bending instabilities should occur even earlier there.

preprint2013arXiv

Characterising the Anisotropic Mechanical Properties of Excised Human Skin

The mechanical properties of skin are important for a number of applications including surgery, dermatology, impact biomechanics and forensic science. In this study we have investigated the influence of location and orientation on the deformation characteristics of 56 samples of excised human skin. Uniaxial tensile tests were carried out at a strain rate of 0.012s$^{-1}$ on skin from the back. Digital Image Correlation was used for 2D strain measurement and a histological examination of the dermis was also performed. The mean ultimate tensile strength (UTS) was 21.6$\pm$8.4MPa, the mean failure strain 54$\pm$17%, the mean initial slope 1.18$\pm$0.88MPa, the mean elastic modulus 83.3$\pm$34.9MPa and the mean strain energy was 3.6$\pm$1.6MJ/m$^3$. A multivariate analysis of variance has shown that these mechanical properties of skin are dependent upon the orientation of Langer lines (P$<$0.0001-P=0.046). The location of specimens on the back was also found to have a significant effect on the UTS (P =0.0002), the elastic modulus (P=0.001) and the strain energy (P=0.0052). The histological investigation concluded that there is a definite correlation between the orientation of Langer Lines and the preferred orientation of collagen fibres in the dermis (P$<$0.001). The data obtained in this study will provide essential information for those wishing to model the skin using a structural constitutive model.