Researcher profile

Adrian L. Malec

Adrian L. Malec contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2016arXiv

Precise limits on cosmological variability of the fine-structure constant with zinc and chromium quasar absorption lines

The strongest transitions of Zn and CrII are the most sensitive to relative variations in the fine-structure constant ($Δα/α$) among the transitions commonly observed in quasar absorption spectra. They also lie within just 40Å of each other (rest frame), so they are resistant to the main systematic error affecting most previous measurements of $Δα/α$: long-range distortions of the wavelength calibration. While Zn and CrII absorption is normally very weak in quasar spectra, we obtained high signal-to-noise, high-resolution echelle spectra from the Keck and Very Large Telescopes of 9 rare systems where it is strong enough to constrain $Δα/α$ from these species alone. These provide 12 independent measurements (3 quasars were observed with both telescopes) at redshifts 1.0--2.4, 11 of which pass stringent reliability criteria. These 11 are all consistent with $Δα/α=0$ within their individual uncertainties of 3.5--13 parts per million (ppm), with a weighted mean $Δα/α= 1.2\pm1.7_{\rm stat}\pm0.9_{\rm sys}$ ppm (1$σ$ statistical and systematic uncertainties), indicating no significant cosmological variations in $α$. This is the first statistical sample of absorbers that is resistant to long-range calibration distortions (at the $<$1 ppm level), with a precision comparable to previous large samples of $\sim$150 (distortion-affected) absorbers. Our systematic error budget is instead dominated by much shorter-range distortions repeated across echelle orders of individual spectra.

preprint2011arXiv

First constraint on cosmological variation of the proton-to-electron mass ratio from two independent telescopes

A high signal-to-noise spectrum covering the largest number of hydrogen lines (90 H2 lines and 6 HD lines) in a high redshift object was analyzed from an observation along the sight-line to the bright quasar source J2123$-$005 with the UVES spectrograph on the ESO Very Large Telescope (Paranal, Chile). This delivers a constraint on a possible variation of the proton-to-electron mass ratio of Dmu/mu = (8.5 \pm 3.6_{stat} \pm 2.2_{syst}) x 10^{-6} at redshift z=2.059$, which agrees well with a recently published result on the same system observed at the Keck telescope yielding Dmu/mu = (5.6 \pm 5.5_{stat} \pm 2.9_{syst}) x 10^{-6}. Both analyses used the same robust absorption line fitting procedures with detailed consideration of systematic errors.

preprint2010arXiv

Keck telescope constraint on cosmological variation of the proton-to-electron mass ratio

Molecular transitions recently discovered at redshift z_abs=2.059 toward the bright background quasar J2123-0050 are analysed to limit cosmological variation in the proton-to-electron mass ratio, mu=m_p/m_e. Observed with the Keck telescope, the optical echelle spectrum has the highest resolving power and largest number (86) of H_2 transitions in such analyses so far. Also, (seven) HD transitions are used for the first time to constrain mu-variation. These factors, and an analysis employing the fewest possible free parameters, strongly constrain mu&#39;s relative deviation from the current laboratory value: dmu/mu =(+5.6+/-5.5_stat+/-2.9_sys)x10^{-6}, indicating an insignificantly larger mu in the absorber. This is the first Keck result to complement recent null constraints from three systems at z_abs>2.5 observed with the Very Large Telescope. The main possible systematic errors stem from wavelength calibration uncertainties. In particular, distortions in the wavelength solution on echelle order scales are estimated to contribute approximately half the total systematic error component, but our estimate is model dependent and may therefore under or overestimate the real effect, if present. To assist future mu-variation analyses of this kind, and other astrophysical studies of H_2 in general, we provide a compilation of the most precise laboratory wavelengths and calculated parameters important for absorption-line work with H_2 transitions redwards of the hydrogen Lyman limit.

preprint2010arXiv

New limit on a varying proton-to-electron mass ratio from high-resolution optical quasar spectra

Molecular transitions recently discovered at redshift z_abs=2.059 toward the bright background quasar J2123-0050 are analysed to limit cosmological variation in the proton-to-electron mass ratio, mu=m_p/m_e. Observed with the Keck telescope, the optical spectrum has the highest resolving power and largest number (86) of H_2 transitions in such analyses so far. Also, (7) HD transitions are used for the first time to constrain mu-variation. These factors, and an analysis employing the fewest possible free parameters, strongly constrain mu&#39;s relative deviation from the current laboratory value: dmu/mu =(+5.6+/-5.5_stat+/-2.7_sys)x10^{-6}. This is the first Keck result to complement recent constraints from three systems at z_abs>2.5 observed with the Very Large Telescope.