Researcher profile

Adam Wittek

Adam Wittek contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Automated modeling of brain bioelectric activity within the 3D Slicer environment

Electrocorticography (ECoG) or intracranial electroencephalography (iEEG) monitors electric potential directly on the surface of the brain and can be used to inform treatment planning for epilepsy surgery when paired with numerical modeling. For solving the inverse problem in epilepsy seizure onset localization, accurate solution of the iEEG forward problem is critical which requires accurate representation of the patient's brain geometry and tissue electrical conductivity. In this study, we present an automatic framework for constructing the brain volume conductor model for solving the iEEG forward problem and visualizing the brain bioelectric field on a deformed patient-specific brain model within the 3D Slicer environment. We solve the iEEG forward problem on the predicted postoperative geometry using the finite element method (FEM) which accounts for patient-specific inhomogeneity and anisotropy of tissue conductivity. We use an epilepsy case study to illustrate the workflow of our framework developed and integrated within 3D Slicer.

preprint2022arXiv

Patient-specific solution of the electrocorticography forward problem in deforming brain

Invasive intracranial electroencephalography (iEEG) or electrocorticography (ECoG) measures electric potential directly on the surface of the brain and can be used to inform treatment planning for epilepsy surgery. Combined with numerical modeling they can further improve accuracy of epilepsy surgery planning. Accurate solution of the iEEG or ECoG forward problem, which is a crucial prerequisite for solving the inverse problem in epilepsy seizure onset zone localization, requires accurate representation of the patient's brain geometry and tissue electrical conductivity after implantation of electrodes. However, implantation of subdural grid electrodes causes the brain to deform, which invalidates preoperatively acquired image data. Moreover, postoperative magnetic resonance imaging (MRI) is incompatible with implanted electrodes and computed tomography (CT) has insufficient range of soft tissue contrast, which precludes both MRI and CT from being used to obtain the deformed postoperative geometry. In this paper, we present a biomechanics-based image warping procedure using preoperative MRI for tissue classification and postoperative CT for locating implanted electrodes to perform non-rigid registration of the preoperative image data to the postoperative configuration. We solve the iEEG forward problem on the predicted postoperative geometry using the finite element method (FEM) which accounts for patient-specific inhomogeneity and anisotropy of tissue conductivity. Results for the simulation of a current source in the brain show large differences in electric potential predicted by the models based on the original images and the deformed images corresponding to the brain geometry deformed by placement of invasive electrodes. Computation of the lead field matrix (useful for solution of the iEEG inverse problem) also showed significant differences between the different models.

preprint2022arXiv

Recovery by discretization corrected particle strength exchange (DC PSE) operators

A new recovery technique based on discretization corrected particle strength exchange (DC PSE) operators is developed in this paper. DC PSE is a collocation method that can be used to compute derivatives directly at nodal points, instead of by projection from Gauss points as is done in many finite element-based recovery techniques. The proposed method is truly meshless and does not require patches of elements to be defined, which makes it generally applicable to point clouds and arbitrary element topologies. Numerical examples show that the proposed method is accurate and robust.

preprint2020arXiv

Mathematical Modeling and Computer Simulation of Needle Insertion into Soft Tissue

In this study we present a kinematic approach to modeling needle insertion into soft tissues. The kinematic approach allows the presentation of the problem as Dirichlet-type (i.e. driven by enforced motion of boundaries) and therefore weakly sensitive to unknown properties of the tissues and needle-tissue interaction. The parameters used in the kinematic approach are straightforward to determine from images. Our method uses Meshless Total Lagrangian Explicit Dynamics (MTLED) framework to compute soft tissue deformations. The proposed scheme was validated against experiments of needle insertion into silicone gel samples. We also present a simulation of needle insertion into the brain demonstrating the method's insensitivity to assumed mechanical properties of tissue.

preprint2020arXiv

Simple and robust element-free Galerkin method with interpolating shape functions for finite deformation elasticity

In this paper, we present a meshless method belonging to the family of element-free Galerkin (EFG) methods. The distinguishing feature of the presented meshless method is that it allows accurate enforcement of essential boundary conditions. The method uses total Lagrangian formulation with explicit time integration to facilitate code simplicity and robust computations in applications that involve large deformations and non-linear materials. We use a regularized weight function, which closely approximates the Kronecker delta, to generate interpolating shape functions. The imposition of the prescribed displacements on the boundary becomes as straightforward as in the finite element (FE) method. The effectiveness and accuracy of the proposed method is demonstrated using 3D numerical examples that include cylinder indentation by 70% of its initial height, and indentation of the brain.

preprint2019arXiv

Wall Stress Distributions in Abdominal Aortic Aneurysms Do Not Correlate With Symptoms

Abdominal aortic aneurysm (AAA) is a permanent and irreversible dilation of the lower region of the aorta. It is typically an asymptomatic condition that if left untreated can expand to the point of rupture. Mechanically-speaking, rupture of an artery occurs when the local wall stress exceeds the local wall strength. It is therefore understandable that numerous studies have attempted to estimate the AAA wall stress. Recently the Intelligent Systems for Medicine Laboratory (ISML) presented a very efficient method to compute AAA wall stress using geometry from Computed Tomography (CT) images, and median arterial pressure as the applied load. The ISML's method is embedded in the software platform BioPARR - Biomechanics based Prediction of Aneurysm Rupture Risk, freely available from http://bioparr.mech.uwa.edu.au/. The uniqueness of our stress computation approach is three-fold: i) the results are insensitive to unknown patient-specific mechanical properties of arterial wall tissue; ii) the residual stress is accounted for, according to Y.C. Fung's Uniform Stress Hypothesis; and iii) the analysis is automated and quick, making our approach compatible with clinical workflows. In this study we evaluated 19 cases of AAA. A proportion of these were classified as symptomatic. The results of the analysis demonstrate, contrary to the common view, that neither the wall stress magnitude nor the stress distribution correlate with the presence of clinical symptoms.