Researcher profile

Adam Rysanek

Adam Rysanek contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2022arXiv

The effect of air purifiers and curtains on aerosol dispersion and removal in multi-patient hospital rooms

Airborne transmission of disease is of concern in many indoor spaces. Here, aerosol dispersion and removal in an unoccupied 4-bed hospital room was characterized using a transient aerosol tracer experiment for 38 experiments covering 4 configurations of air purifiers and 3 configurations of curtains. NaCl particle (mass mean aerodynamic diameter $\sim 3 μm$) concentrations were measured around the room following an aerosol release. Particle transport across the room was 1.5 - 4 minutes which overlaps with the characteristic times for significant viral deactivation and gravitational settling of larger particles. Concentrations were close to spatially uniform except very near the source. Short curtains had no consistent effects on concentrations at the non-source patient locations while floor-length curtains reduced concentrations slightly depending on the purifier configuration. The aerosol decay rate was in most cases higher than expected from the clean air delivery rate, but the reduction in steady-state concentrations resulting from air purifiers was less than suggested by the decay rates. Apparently a substantial (and configuration-dependent) fraction of the aerosol is removed immediately and this effect is not captured by the decay rate. Overall, the combination of curtains and purifiers is likely to reduce disease transmission in multipatient hospital rooms.