Source author record

Abdulaziz Ahmed Al-Hashemi

Abdulaziz Ahmed Al-Hashemi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2020arXiv

Dynamic Ventilatory circuit divider: Safer way to multiply the number of available ventilators

Background: Recent pandemic has brought a sudden surge in the requirement of mechanical ventilators all over the world. In this backdrop, there is wide interest in looking for ways to support multiple patients from a single ventilator. Various solutions, based upon simple mechanical division of the ventilator tubings are described. However, recently warnings have been issued by multiple international professional societies against these plumbing solutions as it can seriously harm the patients. Methods: We have bifurcated the inspiratory and expiratory conduits from a single ventilator with addition of one way valves, pressure and flow sensors along with volume and PEEP control. A purpose-built software and a low-cost microcontroller based control system integrates and displays the data in the familiar ventilatory graphic and numerical format onto a generic screen. The system is calibrated with simulated lungs with varying compliance. In addition to the standard microbial, heat and moisture exchanger filters we design to add UV-C lights at 254-260 nanometre wavelength in the expiratory channel for its virucidal effect. Results: The dynamic ventilatory divider system is capable of providing and controlling individual flow, tidal volume (TV) and Positive End-expiratory pressure (PEEP) for individual patients. Furthermore, it would also display the ventilatory parameters of both the patients, on a single split screen, in a familiar format. FiO2 and rate are still controlled by the mother ventilator. Conclusions: The prototype system has a potential to provide safe ventilation to at least two individuals from a single ventilator, while maintaining the unique requirements of each patient.