Source author record

Abdelrahman Elbadrawy

Abdelrahman Elbadrawy appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Automated Angular Received-Power Characterization of Embedded mmWave Transmitters Using Geometry-Calibrated Spatial Sampling

This paper presents an automated measurement methodology for angular received-power characterization of embedded millimeter-wave transmitters using geometry-calibrated spatial sampling. Characterization of integrated mmWave transmitters remains challenging due to limited angular coverage and alignment variability in conventional probe-station techniques, as well as the impracticality of anechoic-chamber testing for platform-mounted active modules. To address these challenges, we introduce RAPTAR, an autonomous measurement system for angular received-power acquisition under realistic installation constraints. A collaborative robot executes geometry-calibrated, collision-aware hemispherical trajectories while carrying a calibrated receive probe, enabling controlled and repeatable spatial positioning around a fixed device under test. A spectrum-analyzer-based receiver chain acquires amplitude-only received power as a function of angle and distance following quasi-static pose stabilization. The proposed framework enables repeatable angular received-power mapping and power-domain comparison against idealized free-space references derived from full-wave simulation. Experimental results for a 60-GHz radar module demonstrate a mean absolute received-power error below 2 dB relative to simulation-derived references and a 36.5 % reduction in error compared to manual probe-station measurements, attributed primarily to reduced alignment variability and consistent spatial sampling. The proposed method eliminates the need for coherent field measurements and near-field transformations, enabling practical power-domain characterization of embedded mmWave modules. It is well suited for angular validation in real-world platforms where conventional anechoic measurements are impractical.

preprint2026arXiv

Radar-Based Fall Detection for Assisted Living: A Digital-Twin Representation Case Study

Obtaining data on high-impact falls from older adults is ethically difficult, yet these rare events cause many fall-related health problems. As a result, most radar-based fall detectors are trained on staged falls from young volunteers, and representation choices are rarely tested against the radar signals from dangerous falls. This paper uses a frequency-modulated continuous-wave (FMCW) radar digital twin as a single simulated room testbed to study how representation choice affects fall/non-fall discrimination. From the same simulated range-Doppler sequence, Doppler-time spectrograms, three-channel per-receiver spectrogram stacks, and time-pooled range-Doppler maps (RDMs) are derived and fed to an identical compact CNN under matched training on a balanced fall/non-fall dataset. In this twin, temporal spectrograms reach 98-99% test accuracy with similar precision and recall for both classes, while static RDMs reach 89.4% and show more variable training despite using the same backbone. A qualitative comparison between synthetic and measured fall spectrograms suggests that the twin captures gross Doppler-time structure, but amplitude histograms reveal differences in the distributions of amplitude values consistent with receiver processing not modeled in the twin. Because the twin omits noise and hardware impairments and is only qualitatively compared to a single measured example, these results provide representation-level guidance under controlled synthetic conditions rather than ready-to-use clinical performance in real settings.