Researcher profile

A. Waxman

A. Waxman contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

In-vacuum microwave resonator for a compact cold atom frequency standard

A physics package for a compact cold atomic clock is hereby presented. The uniqueness of this package is its small dimensions that enable, for the first time, implementation of a primary cold atomic clock in a standard package of 3U height (=133mm). These dimensions are made possible by using an in-vacuum Microwave (MW) Loop Gap Resonator (LGR) whose length and diameter can be reduced from those of a typical resonator. Following our presentation of the design, we analyze the homogeneity of the MW field amplitude and phase. We find that the expected clock instability due to non-uniformity of the MW field is $\sim1.5\cdot10^{-14}$/day. Adding other clock errors, we estimate the total uncertainty of a cold atomic clock of this design will be around $\sim2\cdot10^{-14}$/day which results in a time drift of a few nanoseconds/day. Such a clock can serve as a primary-grade frequency reference, and may replace the cesium beam atomic clock and the GPS-disciplined rubidium atomic clocks.

preprint2014arXiv

Diamond Magnetometry of Superconducting Thin Films

In recent years diamond magnetometers based on the nitrogen-vacancy (NV) center have been of considerable interest for magnetometry applications at the nanoscale. An interesting application which is well suited for NV centers is the study of nanoscale magnetic phenomena in superconducting materials. We employ the magnetic sensitivity of NV centers in diamond to interrogate the magnetic properties of a thin-layer yttrium barium copper oxide (YBCO) superconductor. Using fluorescence-microscopy methods and samples integrated with an NV sensor on a microchip, we measure the temperature of phase transition in the layer to be 70.0(2) K, and the penetration field of vortices to be 46(4) G. We observe the pinning of the vortices in the layer at 65 K, and estimate their density after cooling the sample in a ~ 10 G field to be 0.45(1) μm^{-2}. These measurements are done with a 10 nm thick NV layer, so that high spatial resolution may be enabled in the future. Based on these results, we anticipate that this magnetometer could be useful for imaging the structure and dynamics of vortices. As an outlook, we present a fabrication method for a superconductor chip designed for this purpose.

preprint2010arXiv

Temperature dependence of the nitrogen-vacancy magnetic resonance in diamond

The temperature dependence of the magnetic resonance spectra of nitrogen-vacancy (NV-) ensembles in the range of 280-330 K was studied. Four samples prepared under different conditions were studied with NV- concentrations ranging from 10 ppb to 15 ppm. For all of these samples, the axial zero-field splitting (ZFS) parameter, D, was found to vary significantly with temperature, T, as dD/dT = -74.2(7) kHz/K. The transverse ZFS parameter, E, was non-zero (between 4 and 11 MHz) in all samples, and exhibited a temperature dependence of dE/(EdT) = -1.4(3) x 10^(-4) K^(-1). The results might be accounted for by considering local thermal expansion. The observation of the temperature dependence of the ZFS parameters presents a significant challenge for room-temperature diamond magnetometers and may ultimately limit their bandwidth and sensitivity.