Source author record

A. V. Derbin

A. V. Derbin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

24works
11topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

24 published item(s)

preprint2026arXiv

Fermionic sub-GeV Dark Matter from evaporating Primordial Black Holes at DarkSide-50

We present a search for boosted dark matter from Primordial Black Holes (PBH) evaporation using the DarkSide-50 ionization-signal-only dataset corresponding to the experiment's ($12202\pm180$) ${\rm kg\: d}$ exposure. We focus on evaporation of PBHs with masses in the range [$10^{14},\,10^{16}$] g producing Dirac fermionic dark matter particles with sub-GeV kinetic energy. These relativistic particles, with energies up to hundreds of MeV, can generate detectable signals for masses below $\mathcal{O}(100)$ MeV. The absence of a signal enables setting complementary limits to those derived from cosmological observations and direct detection searches for cosmic ray-boosted dark matter.

preprint2023arXiv

Investigation of radiation hardness of silicon semiconductor detectors under irradiation with fission products of 252Cf nuclide

Influence of the prolonged irradiation by fission products of 252Cf radionuclide on the operational parameters of silicon-lithium Si(Li) p-i-n detectors, Si surface barrier detectors and Si planar p+n detector was investigated. The obtained results revealed a linear shift of the fission fragment peaks positions towards the lower energies with increase of the irradiation dose for all investigated detectors. The rate of the peaks shift was found to depend strongly on the detector type and the strength of the electric field in the detectors active region, but not on the temperature of irradiation (room or liquid nitrogen temperature). Based on the obtained results, the possibility of integration of the investigated types of Si semiconductor detectors in a radionuclide neutron calibration source is considered.

preprint2022arXiv

New Horizons: Scalar and Vector Ultralight Dark Matter

The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.

preprint2021arXiv

Influence of α-particles irradiation on the performance and defect levels structure of Al/SiO2/p-type Si surface barrier detector

Deterioration of the operation parameters of Al/SiO2/p-type Si surface barrier detector upon irradiation with alpha-particles at room temperature was investigated. As a result of 40-days irradiation with a total fluence of 8*10^9 α-particles, an increase of α-peak FWHM from 70 keV to 100 keV was observed and explained by increase of the detector reverse current due to formation of a high concentration of near mid-gap defect levels. Performed CV measurements revealed the appearance of at least 6*10^12 cm-3 radiation-induced acceptors at the depths where according to the TRIM simulations the highest concentration of vacancy-interstitial pairs was created by the incoming α-particles. The studies carried out by current-DLTS technique allowed to associate the observed increase of the acceptor concentration with the near mid-gap acceptor level at EV+0.56 eV. This level can be apparently associated with V2O defects recognized previously to be responsible for the space charge sign inversion in the irradiated n-type Si detectors.

preprint2021arXiv

Precision measurement of $^{\mathbf{210}}$Bi $β$-spectrum

The precision measurement of the $β-$spectrum shape for $^{210}$Bi (historically RaE) have been performed with a spectrometer based on semiconductor Si(Li) detector. This first forbidden non-unique transition has the transition form-factor strongly deviated from unity and knowledge of its spectrum would play an important role in low-background physics in presence of $^{210}$Pb background. The measured transition form-factor could be approximated as $S(W) = 1 + (-0.4363 \pm 0.0037) W + (0.0523 \pm 0.0010) W^2$, that is in good agreement with previous studies and has significantly increased parameter precision.

preprint2021arXiv

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

preprint2020arXiv

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

preprint2020arXiv

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between $2.4 \times 10^{-45} \, \mathrm{cm}^2$ and $2.3 \times 10^{-42} \, \mathrm{cm}^2$ (8.9 $\times 10^{-45} \, \mathrm{cm}^2$ and 6.0 $\times 10^{-42} \, \mathrm{cm}^2$) for WIMPs of mass of 100 $\mathrm{GeV/c^2}$ (1000 $\mathrm{GeV/c^2}$) at 90\% confidence level.

preprint2020arXiv

New limits on the resonant absorption of solar axions obtained with a $^{169}$Tm-containing cryogenic detector

A search for resonant absorption of solar axions by $^{169}$Tm nuclei was carried out. A newly developed approach involving low-background cryogenic bolometer based on Tm$_3$Al$_5$O$_{12}$ crystal was used that allowed for significant improvement of sensitivity in comparison with previous $^{169}$Tm based experiments. The measurements performed with $8.18$ g crystal during $6.6$ days exposure yielded the following limits on axion couplings: $|g_{Aγ} (g_{AN}^0 + g_{AN}^3) \leq 1.44 \times 10^{-14}$ GeV$^{-1}$ and $|g_{Ae} (g_{AN}^0 + g_{AN}^3) \leq 2.81 \times 10^{-16}$.

preprint2019arXiv

A Test of Bolometric Properties of Tm-containing Crystals as a Perspective Detector for the Solar Axion Search

The $^{169}$Tm nuclide has first nuclear level at 8.41 keV with magnetic type transition to the ground state and, therefore, can be used as a target nucleus for the search of resonant absorption of solar axions. We plan to use a Tm-containing crystal of a garnet family Tm$_3$Al$_5$O$_{12}$ as a bolometric detector in order to search for the excitation of the first nuclear level of $^{169}$Tm via the resonant absorption of solar axions. With this perspective in mind, a sample of the Tm$_3$Al$_5$O$_{12}$ crystal was grown and tested for its bolometric and optical properties. Measurements of chemical and/or radioactive contaminations were performed as well. In this paper we present the test results and estimate the requirements for a future low-background experimental setup.

preprint2016arXiv

A measurement method of a detector response function for monochromatic electrons based on the Compton scattering

In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the scattered photon in the Ge-detector. The novelty of this method is that the source of gamma rays, the germanium and scintillation detectors are immediately arranged adjacent to each other. The method presents an effective solution for the detectors consisting of a low atomic number materials, when the ratio between Compton effect and photoelectric absorption is large and the mean path of gamma-rays is comparable to the size of the detector. The technique can be used for the precision measurements of the scintillator light yield dependence on the electron energy.

preprint2015arXiv

New limit on the mass of 9.4-keV solar axions emitted in an M1 transition in $^{83}$Kr nuclei

A search for resonant absorption of the solar axion by $^{83}\rm{Kr}$ nuclei was performed using the proportional counter installed inside the low-background setup at the Baksan Neutrino Observatory. The obtained model independent upper limit on the combination of isoscalar and isovector axion-nucleon couplings $|g_3-g_0|\leq 1.69\times 10^{-6}$ allowed us to set the new upper limit on the hadronic axion mass of $m_{A}\leq 130$ eV (95\% C.L.) with the generally accepted values $S$=0.5 and $z$=0.56.

preprint2015arXiv

Searches for axioelectric effect of solar axions with BGO-scintillator and BGO-bolometer detectors

A search for axioelectric absorption of 5.5 MeV solar axions produced in the $p + d \rightarrow {^3\rm{He}}+γ~(5.5~ \rm{MeV})$ reaction has been performed with a BGO detectors. A model-independent limit on the product of axion-nucleon $g_{AN}^3$ and axion-electron $g_{Ae}$ coupling constants has been obtained: $| g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90\% C.L..

preprint2014arXiv

Conceptual Design of the International Axion Observatory (IAXO)

The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling $g_{ae}$ with sensitivity $-$for the first time$-$ to values of $g_{ae}$ not previously excluded by astrophysics. With several other possible physics cases, IAXO has the potential to serve as a multi-purpose facility for generic axion and ALP research in the next decade. In this paper we present the conceptual design of IAXO, which follows the layout of an enhanced axion helioscope, based on a purpose-built 20m-long 8-coils toroidal superconducting magnet. All the eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able to focus the signal photons into $\sim 0.2$ cm$^2$ spots that are imaged by ultra-low-background Micromegas x-ray detectors. The magnet is built into a structure with elevation and azimuth drives that will allow for solar tracking for $\sim$12 h each day.

preprint2014arXiv

First result of the experimental search for the 9.4 keV solar axion reactions with Kr-83 in the copper proportional counter

The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m_{A} < 130 eV at 95% C.L.

preprint2014arXiv

Search for axioelectric effect of solar axions using BGO scintillating bolometer

A search for axioelectric absorption of solar axions produced in the $ p + d \rightarrow {^3\rm{He}}+γ~(5.5~ \rm{MeV})$ reactions has been performed with a BGO detector placed in a low-background setup. A model-independent limit on an axion-nucleon and axion-electron coupling constant has been obtained: $| g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90% confidence level. The constrains of the axion-electron coupling have been obtained for hadronic axion with masses in (0.1 - 1) MeV range: $|g_{Ae}| \leq (0.96 - 8.2)\times 10^{-8}$.

preprint2013arXiv

IAXO - The International Axion Observatory

The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic field volume together with the extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested at CAST. Electron-coupled axions invoked to explain the white dwarf cooling, relic axions, and a large variety of more generic axion-like particles (ALPs) along with other novel excitations at the low-energy frontier of elementary particle physics could provide additional physics motivation for IAXO.

preprint2013arXiv

Search for axioelectric effect of 5.5 MeV solar axions using BGO detectors

A search for axioelectric absorption of solar axions produced in the $ p + d \rightarrow {^3\rm{He}}+γ(5.5 \rm{MeV})$ reactions has been performed with a BGO detector placed in a low-background setup. A model-independent limit on an axion-nucleon and axion-electron coupling constant has been obtained: $| g_{Ae}\times g_{AN}^3|< 2.9\times 10^{-9}$ for 90% confidence level. The constrains of the axion-electron coupling have been obtained for hadronic axion with masses in (0.1 - 1) MeV range: $|g_{Ae}| \leq (1.4 - 9.7)\times 10^{-7}$.

preprint2013arXiv

Search for solar axions produced by Compton process and bremsstrahlung using axioelectric effect

The axio-electric effect in silicon atoms is sought for solar axions appearing owing to bremsstrahlung and the Compton process. Axions are detected using a Si(Li) detector placed in a low-background setup. As a result, a model-independent constraint on the axion-electron coupling constant $|g_{Ae}| \leq 2.2\times 10^{-10}$ has been obtained, which leads to the bounds $m_{A}\leq$ 7.9 eV and $m_{A}\leq$ 1.4 keV for the mass of the axion in the DFSZ and KSVZ models, respectively (90% C.L.).

preprint2013arXiv

Search for solar axions produced by Compton process and bremsstrahlung using the resonant absorption and axioelectric effect

The search for resonant absorption of Compton and bremsstrahlung solar axions by $^{169}$Tm nuclei have been performed. Such an absorption should lead to the excitation of low-lying nuclear energy level: $A+^{169}$Tm $\rightarrow ^{169}$Tm$^*$ $\rightarrow ^{169}$Tm $+ γ$ (8.41 keV). Additionally the axio-electric effect in silicon atoms is sought. The axions are detected using a Si(Li) detectors placed in a low-background setup. As a result, a new model independent restrictions on the axion-electron and the axion-nucleon coupling: $g_{Ae}\times|g^0_{AN}+ g^3_{AN}|\leq 2.1\times10^{-14}$ and the axion-electron coupling constant: $|g_{Ae}| \leq 2.2\times 10^{-10}$ has been obtained. The limits leads to the bounds $m_{A}\leq$ 7.9 eV and $m_{A}\leq$ 1.3 keV for the mass of the axion in the DFSZ and KSVZ models, respectively ($90\%$ C.L.).

preprint2012arXiv

Search for neutrino oscillations at a research reactor

A project of search for oscillations of reactor neutrinos on a short, 5 - 15 meters, baseline with liquid scintillation position-sensitive detector POSEIDON is described. The oscillations of the electron antineutrinos into sterile neutrinos will be searched at 100 MW research reactor with the size of the active zone of about 0.5 m. The values of the oscillation parameters available for research are in the region $δm^2 = (0.3 - 6) \rm{eV}^2$ and $\rm{Sin}^2(2θ)\geq 0.01$.

preprint2011arXiv

Constraints on the axion-electron coupling for solar axions produced by Compton process and bremsstrahlung

The search for solar axions produced by Compton ($γ+e^-\rightarrow e^-+A$) and bremsstrahlung-like ($e^-+Z \rightarrow Z+e^-+A$) processes has been performed. The axion flux in the both cases depends on the axion-electron coupling constant. The resonant excitation of low-lying nuclear level of $^{169}\rm{Tm}$ was looked for: $A+^{169}$Tm $\rightarrow ^{169}$Tm$^*$ $\rightarrow ^{169}$Tm $+ γ$ (8.41 keV). The Si(Li) detector and $^{169}$Tm target installed inside the low-background setup were used to detect 8.41 keV $γ$-rays. As a result, a new model independent restriction on the axion-electron and the axion-nucleon couplings was obtained: $g_{Ae}\times|g^0_{AN}+ g^3_{AN}|\leq 2.1\times10^{-14}$. In model of hadronic axion this restriction corresponds to the upper limit on the axion-electron coupling and on the axion mass $g_{Ae}\times m_A\leq3.1\times10^{-7}$ eV (90% c.l.). The limits on axion mass are $m_A\leq$ 105 eV and $m_A\leq$ 1.3 keV for DFSZ- and KSVZ-axion models, correspondingly (90% c.l.).

preprint2010arXiv

Search for Solar Axions Produced in the $p + d \rightarrow\rm{^3He}+ A$ Reaction

A search for the axioelectric absorption of 5.5-MeV solar axions produced in the $p+d\rightarrow \rm{^3He}+γ(5.5 \rm{MeV})$ reaction was performed with two BGO detectors placed inside a low-background setup. A model independent limit on axion-photon and axion-nucleon couplings was obtained: $|g_{Ae}\times g_{AN}| \leq 3.2\times 10^{-9} (m_A=0)$. Constraints on the axion-electron coupling constant were obtained for axions with masses in the $(0.1-1.0)$ MeV range: $g_{Ae}\leq (1.8-9.0)\times 10^{-7}$. The solar positron flux from $A\rightarrow e^-+e^+$ decay was determined for axions with masses $m_A > 2m_e$. Using the existing experimental data on the interplanetary positron flux, a new constraint on the axion-electron coupling constant for axions with masses in the $(1.2-5.4)$ MeV range was obtained: $g_{Ae} \leq (1-5)\times 10^{-17}$.