Source author record

A. M. Davidenko

A. M. Davidenko appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2018arXiv

Proton Form Factor Ratio, $μ_p G_E^p/G_M^p$ from Double Spin Asymmetry

The ratio of the electric and magnetic form factor of the proton, $μ_p G_E^p/G_M^p$, has been measured for elastic electron-proton scattering with polarized beam and target up to four-momentum transfer squared, $Q^2=5.66$ (GeV/c)$^2$ using the double spin asymmetry for target spin orientation aligned nearly perpendicular to the beam momentum direction. This measurement of $μ_p G_E^p/G_M^p$ agrees with the $Q^2$ dependence of previous recoil polarization data and reconfirms the discrepancy at high $Q^2$ between the Rosenbluth and the polarization-transfer method with a different measurement technique and systematic uncertainties uncorrelated to those of the recoil-polarization measurements. The form factor ratio at $Q^2$=2.06 (GeV/c)$^2$ has been measured as $μ_p G_E^p/G_M^p = 0.720 \pm 0.176_{stat} \pm 0.039_{sys}$, which is in agreement with an earlier measurement with the polarized target technique at similar kinematics. The form factor ratio at $Q^2$=5.66 (GeV/c)$^2$ has been determined as $μ_p G_E^p/G_M^p=0.244\pm0.353_{stat}\pm0.013_{sys}$, which represents the highest $Q^2$ reach with the double spin asymmetry with polarized target to date.

preprint2012arXiv

Technical Design Report for the: PANDA Micro Vertex Detector

This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.

preprint2005arXiv

Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter

A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.