Source author record

A. Lanz

A. Lanz appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Cyclotron cooling to cryogenic temperature in a Penning-Malmberg trap with a large solid angle acceptance

Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, resulting in significantly reduced plasma temperature.

preprint2022arXiv

Minimizing plasma temperature for antimatter mixing experiments

The ASACUSA collaboration produces a beam of antihydrogen atoms by mixing pure positron and antiproton plasmas in a strong magnetic field with a double cusp geometry. The positrons cool via cyclotron radiation inside the cryogenic trap. Low positron temperature is essential for increasing the fraction of antihydrogen atoms which reach the ground state prior to exiting the trap. Many experimental groups observe that such plasmas reach equilibrium at a temperature well above the temperature of the surrounding electrodes. This problem is typically attributed to electronic noise and plasma expansion, which heat the plasma. The present work reports anomalous heating far beyond what can be attributed to those two sources. The heating seems to be a result of the axially open trap geometry, which couples the plasma to the external (300 K) environment via microwave radiation.

preprint2015arXiv

Measurements of the mean diffuse galactic light spectrum in the 0.95 μm to 1.65 μm band from CIBER

We report measurements of the Diffuse Galactic Light (DGL) spectrum in the near-infrared, spanning the wavelength range 0.95-1.65 μm by the Cosmic Infrared Background ExpeRiment (CIBER). Using the low-resolution spectrometer (LRS) calibrated for absolute spectro-photometry, we acquired long-slit spectral images of the total diffuse sky brightness towards four high-latitude fields spread over four sounding rocket flights. To separate the DGL spectrum from the total sky brightness, we correlated the spectral images with a 100 μm intensity map, which traces the dust column density in optically thin regions. The measured DGL spectrum shows no resolved features and is consistent with other DGL measurements in the optical and at near-infrared wavelengths longer than 1.8 μm. Our result implies that the continuum is consistently reproduced by models of scattered starlight in the Rayleigh scattering regime with a few large grains.

preprint2013arXiv

The Cosmic Infrared Background Experiment (CIBER): the Narrow Band Spectrometer

We have developed a near-infrared spectrometer designed to measure the absolute intensity of the Solar 854.2 nm CaII Fraunhofer line, scattered by interplanetary dust, in the Zodiacal light spectrum. Based on the known equivalent line width in the Solar spectrum, this measurement can derive the Zodiacal brightness, testing models of the Zodiacal light based on morphology that are used to determine the extragalactic background light in absolute photometry measurements. The spectrometer is based on a simple high-resolution tipped filter placed in front of a compact camera with wide-field refractive optics to provide the large optical throughput and high sensitivity required for rocket-borne observations. We discuss the instrument requirements for an accurate measurement of the absolute Zodiacal light brightness, the measured laboratory characterization, and the instrument performance in flight.