Source author record

A. J. Przybysz

A. J. Przybysz appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2014arXiv

Entanglement in a quantum annealing processor

Entanglement lies at the core of quantum algorithms designed to solve problems that are intractable by classical approaches. One such algorithm, quantum annealing (QA), provides a promising path to a practical quantum processor. We have built a series of scalable QA processors consisting of networks of manufactured interacting spins (qubits). Here, we use qubit tunneling spectroscopy to measure the energy eigenspectrum of two- and eight-qubit systems within one such processor, demonstrating quantum coherence in these systems. We present experimental evidence that, during a critical portion of QA, the qubits become entangled and that entanglement persists even as these systems reach equilibrium with a thermal environment. Our results provide an encouraging sign that QA is a viable technology for large-scale quantum computing.

preprint2013arXiv

Tunneling spectroscopy using a probe qubit

We describe a quantum tunneling spectroscopy technique that requires only low bandwidth control. The method involves coupling a probe qubit to the system under study to create a localized probe state. The energy of the probe state is then scanned with respect to the unperturbed energy levels of the probed system. Incoherent tunneling transitions that flip the state of the probe qubit occur when the energy bias of the probe is close to an eigenenergy of the probed system. Monitoring these transitions allows the reconstruction of the probed system eigenspectrum. We demonstrate this method on an rf SQUID flux qubit.

preprint2010arXiv

Multi-level Spectroscopy of Two-Level Systems Coupled to a dc SQUID Phase Qubit

We report spectroscopic measurements of discrete two-level systems (TLSs) coupled to a dc SQUID phase qubit with a 16 μ\m2 area Al/AlOx/Al junction. Applying microwaves in the 10 GHz to 11 GHz range, we found eight avoided level crossings with splitting sizes from 10 MHz to 200 MHz and spectroscopic lifetimes from 4 ns to 160 ns. Assuming the transitions are from the ground state of the composite system to an excited state of the qubit or an excited state of one of the TLS states, we fit the location and spectral width to get the energy levels, splitting sizes and spectroscopic coherence times of the phase qubit and TLSs. The distribution of splittings is consistent with non-interacting individual charged ions tunneling between random locations in the tunnel barrier and the distribution of lifetimes is consistent with the AlOx in the junction barrier having a frequency-independent loss tangent. To check that the charge of each TLS couples independently to the voltage across the junction, we also measured the spectrum in the 20-22 GHz range and found tilted avoided level crossings due to the second excited state of the junction and states in which both the junction and a TLS were excited.

preprint2007arXiv

Comparison of coherence times in three dc SQUID phase qubits

We report measurements of spectroscopic linewidth and Rabi oscillations in three thin-film dc SQUID phase qubits. One device had a single-turn Al loop, the second had a 6-turn Nb loop, and the third was a first order gradiometer formed from 6-turn wound and counter-wound Nb coils to provide isolation from spatially uniform flux noise. In the 6 - 7.2 GHz range, the spectroscopic coherence times for the gradiometer varied from 4 ns to 8 ns, about the same as for the other devices (4 to 10 ns). The time constant for decay of Rabi oscillations was significantly longer in the single-turn Al device (20 to 30 ns) than either of the Nb devices (10 to 15 ns). These results imply that spatially uniform flux noise is not the main source of decoherence or inhomogenous broadening in these devices.