Source author record

A. Herrmann

A. Herrmann appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Design and simulation of an Imaging Neutral Particle Analyzer for the ASDEX Upgrade tokamak

An Imaging Neutral Particle Analyser (INPA) diagnostic has been designed for the ASDEX Upgrade (AUG) tokamak. The AUG INPA diagnostic will measure fast neutrals escaping the plasma after CX reactions. The neutrals will be ionised by a 20 nm carbon foil and deflected towards a scintillator by the local magnetic field. The use of a neutral beam injector (NBI) as active source of neutrals will provide radially resolved measurements while the use of a scintillator as active component will allow us to cover the whole plasma along the NBI line with unprecedented phase-space resolution ($ < $ 12 keV and 8 cm) and fast temporal response (up to 1 kHz with the high resolution acquisition system and above 100 kHz with the low resolution one); making it suitable to study localised fast-ions redistributions in phase-space.

preprint2016arXiv

ExB analyzer for fast ion temperature measurements in scrape-off layer of the ASDEX Upgrade and COMPASS tokamaks

Ion temperature in the scrape-off layer is an important quantity but rarely measured at high temporal resolution. In order to achieve fast measurements during intermittent events such as blobs, a novel ExB analyzer has been designed. The measurement with the E$\times$B analyzer does not require voltage sweeping but records ion current on DC biased collectors, meaning that the temporal resolution is only limited by the sampling frequency of the data acquisition system and electronics of the amplifiers, which exceeds the typical timescale of events of interest (~10 microseconds). The analyzer is equipped with entrance slit of optimized knife-edge shape, which reduces selective ion losses and improves overall ion transmission. The design of the analyzer is presented together with first acquired signals and reconstructed temperatures.