Researcher profile

A. Cotta Ramusino

A. Cotta Ramusino contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Development of a single-photon imaging detector with pixelated anode and integrated digital read-out

We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating the analog and digital-front end electronics. This assembly will be capable of detecting up to $10^9$ photons per second with simultaneous measurement of position and time. The pixelated read-out anode used is based on the Timepix4 ASIC ($65~\mathrm{nm}$ CMOS technology) designed in the framework of the Medipix4 collaboration. This ASIC is an array of $512\times448$ pixels distributed on a $55~\mathrm{μm}$ square pitch, with a sensitive area of $\sim 7~\mathrm{cm}^2$. It features $50$-$70~\mathrm{e^{-}}$ equivalent noise charge, a maximum rate of $2.5~\mathrm{Ghits/s}$, and allows to time-stamp the leading-edge time and to measure the Time-over-Threshold (ToT) for each pixel. The pixel-cluster position combined with its ToT information will allow to reach $5$-$10~\mathrm{μm}$ position resolution. This information can also be used to correct for the leading-edge time-walk achieving a timing resolution of the order of $10~\mathrm{ps}$. The detector will be highly compact thanks to the encapsulated front-end electronics allowing local data processing and digitization. An FPGA-based data acquisition board, placed far from the detector, will receive the detector hits using $16$ electro-optical links operated at $10.24~\mathrm{Gbps}$. The data acquisition board will decode the information and store the relevant data in a server for offline analysis. These performance will allow significant advances in particle physics, life sciences, quantum optics or other emerging fields where the detection of single photons with excellent timing and position resolutions are simultaneously required.

preprint2020arXiv

Time performance of a triple-GEM detector at high rate

Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber ($\upmu$TPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to $10^8\,$Hz/cm$^2$. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the $\upmu$TPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.

preprint2019arXiv

A fast and parametric digitization for triple-GEM detectors

Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.

preprint2019arXiv

GRAAL: Gem Reconstruction And Analysis Library

MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measurethe performance of a MPGD detector with a strip segmented anode (presently). The code isdivided in three parts: reconstruction, where the hits are digitized and clusterized; tracking,where a procedure fits the points from the tracking system and uses that information to align thechamber with rotations and shifts; analysis, where the performance is evaluated (e.g. efficiency,spatial resolution,etc.). The user must set the geometry of the setup and then the programreturns automatically the analysis results, taking care of different conditions of gas mixture,electric field, magnetic field, geometries, strip orientation, dead strip, misalignment and manyothers.