Source author record

A. Carew

A. Carew appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Demonstration of improved sensitivity of echo interferometers to gravitational acceleration

We have developed two configurations of an echo interferometer that rely on standing wave excitation of a laser-cooled sample of rubidium atoms that measures acceleration. For a two-pulse configuration, the interferometer signal is modulated at the recoil frequency and exhibits a sinusoidal frequency chirp as a function of pulse spacing. For a three-pulse stimulated echo configuration, the signal is observed without recoil modulation and exhibits a modulation at a single frequency. The three-pulse configuration is less sensitive to effects of vibrations and magnetic field curvature leading to a longer experimental timescale. For both configurations of the atom interferometer (AI), we show that a measurement of acceleration with a statistical precision of 0.5% can be realized by analyzing the shape of the echo envelope that has a temporal duration of a few microseconds. Using the two-pulse AI, we obtain measurements of acceleration that are statistically precise to 6 parts per million (ppm) on a 25 ms timescale. Using the three-pulse AI, we obtain measurements of acceleration that are statistically precise to 0.4 ppm on a timescale of 50 ms. A further statistical enhancement is achieved by analyzing the data across the echo envelope to improve the statistical precision to 75 parts per billion (ppb). We discuss methods for reducing prominent systematic effects due to a magnetized vacuum chamber and improving the signal-to-noise ratio. Simulations of both AI configurations with a timescale of 300 ms reached in a non-magnetic vacuum chamber suggest that an optimized experiment with improved vibration isolation and atoms selected in the mF = 0 state can result in measurements of g statistically precise to 0.3 pbb for the two-pulse AI and 0.6 ppb for the three-pulse AI.

preprint2013arXiv

Measuring the atomic recoil frequency using a perturbative grating-echo atom interferometer

We describe progress toward a precise measurement of the recoil energy of an atom measured using a perturbative grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, a perturbing sw pulse is used to shift the phase of excited momentum states---producing a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2ω_q$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\lesssim 5$ $μ$K in a non-magnetic apparatus. We demonstrate a measurement of $ω_q$ with a statistical uncertainty of 37 parts per $10^9$ (ppb) on a time scale of $\sim 45$ ms in 14 hours. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\sim 6$ parts per $10^6$ (ppm). We describe methods of reducing these systematic errors.